Vital signs monitoring using Doppler radar and on-body antennas

Tariq, Abubakar (2013). Vital signs monitoring using Doppler radar and on-body antennas. University of Birmingham. Ph.D.

[img]
Preview
Tariq13PhD.pdf
PDF - Redacted Version

Download (10MB)

Abstract

The chest of a person moves due to the heart beating and the lungs expanding and contracting. So the chest movement contains information about the heart and breathing rates. This property is used to detect vital signs using Doppler radar and On-Body antennas. These methods can be accurate, cost-effective, portable, comfortable and low profile alternatives to present commercial heart and breathing rate monitoring devices. The 1st method employing Doppler Effect is non-contact. It detects both the heart and breathing rates using the modulated reflected signals from the chest of a person. A parametric study is conducted considering frequency, power and distance to determine the best parameters for maximum accuracy. A small population study is conducted considering 5 people to validate the accuracy and working of Doppler radar as a vital signs monitor. The 2nd method monitors the heart and breathing rates by sensing motion in the near field proximity of an antenna using the antenna’s reflection coefficient. Simulation studies are conducted using CST chest models to verify the principle. An extensive parametric investigation considering frequency, antenna type, power, antenna location on body, body Position, and distances (between chest and antenna) is conducted to find parameters for maximum detection accuracy. A human population study considering 13 people is conducted to establish heart rate and heart rate variability (HRV) measurement feasibility. A signal processing study is also performed and the best algorithms are identified for accurate detection of vital signs. Besides this novel frequency and pattern reconfigurable antennas are proposed and designed for communications and/or vital signs monitoring purposes.

Type of Work: Thesis (Doctorates > Ph.D.)
Award Type: Doctorates > Ph.D.
Supervisor(s):
Supervisor(s)EmailORCID
Ghafouri-Shiraz, H.UNSPECIFIEDUNSPECIFIED
Licence:
College/Faculty: Colleges (2008 onwards) > College of Engineering & Physical Sciences
School or Department: School of Electronic, Electrical and Computer Engineering
Funders: None/not applicable
Subjects: R Medicine > R Medicine (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
URI: http://etheses.bham.ac.uk/id/eprint/4332

Actions

Request a Correction Request a Correction
View Item View Item

Downloads

Downloads per month over past year